[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: I don't find information about this error



Matthew Knepley wrote:
1) The error message is wrong. I fixed this in the dev tree.

2) 'fill' is the fill ratio for speculative allocation. It looks like
    you gave PETSC_DEFAULT which is invalid. You need to
    give a real number (the ratio of the final to initial allocation)
    so it should be > 1.0.


Ok. I write "1" and runs. You guessed, after I writed "PETSC_DEFAULT".... but, I don't know/understand the value of "fill". There is a default value for this parameter??? What is the best input???

thanks,
jordi

PD: the solution was easy but the message "Nonconforming object sizes!" confused me.


Matt

On 7/14/06, *Jordi Marcé Nogué* <jordi.marce@xxxxxxx <mailto:jordi.marce@xxxxxxx>> wrote:


Hello,

    I'm using Petsc 2.3.1 in Debian (updated by apt-get) and I don't find
    information in the web and in the troubleshooting section about this
    error message:

     > [0]PETSC ERROR: MatMatMult() line 6543 in src/mat/interface/matrix.c
     > [0]PETSC ERROR: Nonconforming object sizes!
     > [0]PETSC ERROR: fill=-2 must be > 0.0!

    Maybe you know what does it mean because I've tried a lot of thing in my
    code to solve this problem :-((( My Matrices have the same dimension.

    regards,\j



    --
    Jordi Marcé-Nogué
    Dept. Resistència de Materials i Estructures a l'Enginyeria
    Universitat Politècnica de Catalunya (UPC)

    Edifici T45 - despatx 137
    ETSEIAT (Terrassa)

    phone: +34 937 398 728
    mail: jordi.marce@xxxxxxx <mailto:jordi.marce@xxxxxxx>




--
"Failure has a thousand explanations. Success doesn't need one" -- Sir Alec Guiness


--
Jordi Marcé-Nogué
Dept. Resistència de Materials i Estructures a l'Enginyeria
Universitat Politècnica de Catalunya (UPC)

Edifici T45 - despatx 137
ETSEIAT (Terrassa)

phone: +34 937 398 728
mail: jordi.marce@xxxxxxx