Natalia:
It sounds like you are using a bridge. If so, the problem is that
the bridge only
sends data to a single application per machine, so only one of your
vic instances
will get video data from the bridge. This is a known bug in our
bugzilla.
If you are not using a bridge, please let us know, as this would be some
strange behavior.
Thanks,
Tom
Natalia Costas wrote:
Hi everybody,
Giving a hand to our collegues at the University of Extremadura, we
found a problem. Maybe someone knows the solution. The problem
arises with a one machine node with two capture cards:
They have 2 videoproducer services + 1 videoconsumer. The problem is
that the videofeeds go to any of the vics (video producer of
videoconsumer) randomly... so.. sometimes the videoconsumer vic
receives nothing (but the videoproducer vic does), and it starts
receiving the feeds only when i close one of the video producer vics.
The only workaround i've found is to add 2 video services (so any of
them receive the feeds and are unmuted). Both receive all the feeds,
but i dont like that solution very much. I am afraid it might have
some impact on performance (the videostreams are delivered to two
different applications...)
Thanx a lot in advance,
Kind regards.