Re: [AG-TECH] Problem with BridgeServer
Hi Tom!
The bridge server advertises itself using poly.fe.up.pt. As I told you,
people from outside can see it and switch to Unicast using it.
If someone on this list has 5 minutes for this, can you please try to
connect to my server and see if RAT and Unicast work properly?
The address is: https://silicon.fe.up.pt:8000/Venues/default
I will be always connected to the server, altough I might not be at the
machine, but can you please check at least if both of us appear in the
RAT window.
Thanks,
Sebastian
Thomas D. Uram wrote:
I suspect that the bridge server is advertising itself using the internal
IP. When external clients try to use the bridge, what address/hostname
appears in RAT?
If this is the problem, you can control the IP address used by the
BridgeServer
(and other AG components) by setting the GLOBUS_HOSTNAME environment
variable to the desired address/hostname.
Tom
On 2/27/06 9:29 AM, Sebastian Tabarce wrote:
Hello!
I have the folowing setup for an AG Venue Server and an AG Bridge
Server:
- the Venue Server: one machine running Fedora Core 4 and AGTK 2.4.
This machine has the internal IP 192.168.103.55 and the domain name
silicon.fe.up.pt. This machine has linked to it the real IP address
193.136.28.183. I don't know exactly what this means in terms of
networking, I just asked my network admin to make my machine visible
to the Internet and he told me that my machine can be seen from the
Internet with this address and also by its name silicon.fe.up.pt.
Ports 8000, 8002, 8004, 8006 TCP are opened for this machine.
- the Bridge Server is running Slackware 10 and AGTK 2.4. Same as
above, internal IP is 192.168.103.62, external IP is 192.136.28.184.
and name poly.fe.up.pt. Ports 50000-50010 UDP are opened.
I've conducted some tests. On the internal network everything works
fine. From outside, people can connect to my Venue Server using
https://silicon.fe.up.pt:8000/Venues/default , they see the
BridgeServer and can choose Unicast, however they do not appear in my
RAT window and, of course, I cannot talk to them. Multicast is not an
option. Also no output in the terminal of the BridgeServer for
machines trying to connect from outside. For those on the local
network I have the normal output.
Any thoughts about why the Bridge Server is not doing its job?
Thanks,
Sebastian
--
Sebastian Tabarce
Junior Researcher
INESC Porto
Campus da FEUP - Rua Dr. Roberto Frias, nš 378
4200-465 Porto Portugal
E-mail : stabarce@inescporto.pt
Web : http://www.inescporto.pt