Seung Lee
Biofluids Laboratory
University of Illinois, Chicago
Paul F. Fischer
Mathematics and Computer Science Division
Argonne National Laboratory, Argonne, IL
Spanwise vorticity in the centerplane of an arteriovenous graft model at Re=1820, based on graft diameter and mean flow rate. Numerical studies conducted by Seung Lee and Paul Fischer.
Experimental/numerical comparison at Re=1060
Experimental/numerical comparison at Re=1820
Last update: 4-22-2000 (pff)